Skip Navigation
Find a Stockist

Technical - Pennine Slate

 

 Pennine Major and Pennine Minor

*

Pennine Minor 480 x 280 - Technical Data

*
Minimum roof pitch
25° at 75 mm headlap
22.5° at 90 mm headlap
Headlap (minimum)
75 mm at 25° roof pitch
90 mm at 22.5° roof pitch
Headlap (maximum)
120 mm
Batten spacing at maximum gauge
202 mm at 75 mm headlap
195 mm at 90 mm headlap
Batten spacing at minimum gauge
180 mm
Size of tile
480 x 280 mm
Covering capacity at maximum gauge
17.7 tiles per m² at 75 mm headlap
18.3 per m² at 90 mm headlap
Cover width
280 mm
Weight as laid
74.3 kg per m² at 75 mm headlap
76.9 per m² at 90 mm headlap
Weight per 1000
4.2 tonnes
Weight per tile
4.2 kg
Weight per pallet (including pallet & packaging)
0.7 tonnes
Quantity per pallet
160
Battens per m²
4.95 m at 75 mm headlap
5.13 m at 90 mm headlap
Batten size - up to 600 mm rafter centres
50 x 25 mm
Nail type/size for slates
38 x 3.35 mm aluminium alloy
Nail type/size for tile clips
N/A
* * *

Note: Unless otherwise stated, data is based on slates laid at minimum headlap

*

Pennine Major 480 x 420 - Technical Data

*
Minimum roof pitch
25° at 75 mm headlap
22.5° at 90 mm headlap
Headlap (minimum)
75 mm at 25° roof pitch
90 mm at 22.5 roof pitch
Headlap (maximum)
120 mm
Batten spacing at maximum gauge
202 mm at 75mm headlap
195 mm at 90 mm headlap
Batten spacing at minimum gauge
180 mm
Size of tile
480 x 420 mm
Covering capacity at maximum gauge
11.8 tiles per m² at 75 mm headlap
12.2 tiles per m² at 90 mm headlap
Cover width
420 mm
Weight as laid
79.2 kg per m² at 75mm headlap
82.1 kg per m² at 90 mm headlap
Weight per 1000
6.7 tonnes
Weight per tile
6.7 kg
Weight per pallet (including pallet and packaging)
0.7 tonnes
Quantity per pallet
106
Battens per m²
4.95 m at 75 mm headlap
5.13 m at 90 mm headlap
Batten size - up to 600 mm rafter centres
50 x 25 mm
Nail type/size for slates
38 x 3.35 mm aluminium alloy
Nail type/size for tile clips
N/A
* * *
 
Note: Unless otherwise stated, data is based on slates laid at minimum headlap
 
For projects where the rafters are below the minimum recommended roof pitch, please contact our Technical Department for advice.
 

Tile Fixing

Sandtoft roof slates must be laid and fixed to comply with BS 5534: the British Standard Code of practice for slating and tiling, and BS 8000: Part 6: the British Standard Code of practice for workmanship on building sites.
 
To ensure compliance with these Standards we strongly recommend that either the recommendations given in the Sandtoft Zonal Method User’s Guide and Zonal tables must be followed where available or a calculated fixing specification must be obtained using Sandtoft’s Fixing SPEC service.
 
For further information go to Fixing SPEC or contact Sandtoft Technical Support on 0870 145 2021