Technical - BritSlate

 BritSlate

*

Britslate Countess 510 x 255 - Technical Data

*
Minimum roof pitch*
22.5°
Size of slate
510 x 255 mm
Cover width
255 mm
Profile depth
6 mm
Weight per 1000
1.3 tonnes
Weight per slate
1.3 kg
Weight per crate (including pallet/packaging)
1.4 tonnes
Quantity per crate
1000 tiles
Batten size - up to 600 mm rafter centres
50 x 25 mm
Nail type/size for slates
38 x 2.75 mm copper clout head
* * *

* Note: Unless otherwise stated, data is based on slates laid at minimum headlap

*

Britslate Duchess 610 x 305 - Technical Data

*
Minimum roof pitch*
20°
Size of slate
610 x 305 mm
Cover width
305 mm
Profile depth
6 mm
Weight per 1000
2.0 tonnes
Weight per slate
2.0 kg
Weight per crate (including pallet/packaging)
1.5 tonnes
Quantity per crate
750 slates
Batten size - up to 600 mm rafter centres
50 x 25 mm
Nail type/size for slates
38 x 2.75 mm copper clout head
* * *

 

* Note: Unless otherwise stated, data is based on slates laid at minimum headlap.
 
Rafter length restrictions apply at minimum roof pitch.  Please contact Technical Support for further information.
 
After installation, natural weathering of the recycled slate will result in a change to the exposed surface, replicating the appearance of natural slate. Contact Sandtoft Technical Support for further information or to request a mini-sample which shows the comparative change to the surface appearance due to weathering, the rate of which depends on the local environment, climate and aspect of the roof.
 
Slight colour variations may exist between batches. Slates should be randomised on site to achieve a consistent appearance when installed.
 
 
*

Moderate Exposure

*
Rafter pitch
20°
22.5°
25°
30°
35°
40°
45°
69°
Headlap (minimum)
Duchess
Countess
 
130
-
 
115
115
 
90
90
 
75
75
 
75
75
 
65
65
 
65
65
 
-
65
Coverage (m²)
Duchess
Countess
 
13.7
-
 
13.2
19.8
 
12.6
18.7
 
12.2
18.0
 
12.2
18.0
 
12.0
17.6
 
12.0
17.6
 
-
17.6
Batten Gauge (mm)
Duchess
Countess
 
240
-
 
247
197
 
260
210
 
267
217
 
267
217
 
272
222
 
272
222
 
-
222
Battens per m²
Duchess
Countess
 
4.16
-
 
4.05
5.08
 
3.84
4.76
 
3.74
4.61
 
3.68
4.65
 
3.68
4.5
 
-
4.5
 
-
4.5
Weight as laid (kg per m²)
Duchess
Countess
 
27.4
-
 
26.4
25.7
 
25.2
24.3
 
24.4
23.4
 
24.4
23.4
 
24.0
22.9
 
24.0
22.9
 
-
22.9
* * *
 
 
*
Severe Exposure
*
Rafter pitch
20°
22.5°
25°
30°
35°
40°
45°
69°
Headlap (minimum)
Duchess
Countess
 
-
-
 
130
-
 
120
115
 
110
100
 
90
90
 
80
75
 
75
75
 
-
75
Coverage (m²)
Duchess
Countess
 
-
-
 
13.7
-
 
13.4
19.8
 
13.1
19.1
 
12.6
18.7
 
12.4
18.0
 
12.2
18.0
 
-
18.0
Batten Gauge (mm)
Duchess
Countess
 
-
-
 
240
-
 
245
197
 
250
205
 
260
210
 
265
217
 
267
217
 
-
217
Battens per m²
Duchess
Countess
 
-
-
 
4.16
-
 
4.08
5.08
 
4.00
4.88
 
3.84
4.76
 
3.77
4.61
 
3.74
4.61
 
-
4.61
Weight as laid (kg per m²)
Duchess
Countess
 
-
-
 
27.4
-
 
26.8
25.7
 
26.2
24.8
 
25.2
24.3
 
24.8
23.4
 
24.4
23.4
 
-
23.4
*
*
*
 
 

Tile Fixing

Sandtoft roof slates must be laid and fixed to comply with BS 5534: the British Standard Code of practice for slating and tiling, and BS 8000: Part 6: the British Standard Code of practice for workmanship on building sites.
To ensure compliance with these Standards we strongly recommend that either the recommendations given in the Sandtoft Zonal Method User’s Guide and Zonal tables must be followed where available or a calculated fixing specification must be obtained using Sandtoft’s Fixing SPEC service.
 
For further information go to Fixing SPEC or contact Sandtoft Technical Support on 0870 145 2021